TESTING STANDARDS
METHOD-810G
|
![]() |
![]() |
![]() |
![]() |
|---|
Water Immersion METHOD 512.5 Procedure I |
Immersed at 3.28 feet (1 meter) depth for 30 minutes | ||||
|---|---|---|---|---|---|
Blowing Rain METHOD 506.5 Procedure I |
Each phone face is exposed to a rainfall rate of 4 inches (.10 meters) per hour, 40 mph wind for 30 minutes | ||||
DROP METHOD 516.6 Procedure IV |
Dropped 4 feet (1.22 meters) 26 times | ||||
Dust METHOD 510.5 Procedure I |
Exposed to heavy dust for 6 hours | ||||
VIBRATION METHOD 514.6 Category 24 |
Vibrated horizontally, vertically and sideways for 1 hour | ||||
SALT FOG METHOD 509.5 |
Exposure to salt fog for a complete 48 hour cycle; this cycle included 24 hours exposure to salt fog followed by 24 hours drying time | ||||
HUMIDITY METHOD 507.5 Procedure II |
Exposed to 95% Humidity for 24 hours, 10 days | ||||
SOLAR RADIATION METHOD 505.5 Procedure I |
Exposed to Solar Radiation 1120 W/m2 for 24 hours | ||||
LOW PRESSURE METHOD 500.5 Procedure II |
Exposed to low pressure at 57.11kPa/ 15,000 feet (4,572 meters) for 2 hours | ||||
HIGH TEMPERATURE METHOD 501.5 Procedure II |
Non-operating unit exposed to 140°F (60°C) for 2 hours; same unit operating exposed to 122°F (50°C) for 3 hours | ||||
LOW TEMPERATURE METHOD 502.5 Procedure I |
Non-operating unit exposed to -22°F (-30°C); same unit operating exposed to -4°F (-20°C) | Non-operating unit exposed for 3 hours; operating unit for 2.5 hours | Non-operating unit exposed for 2 hours; operating unit for 2 hours | Non-operating unit exposed for 3 hours; operating unit for 2.5 hours |